512A5-22-700 | EHRM Infra Upgrades | Perry Point, MD CO: Samantha Mihaila CS: Ric Sochor
Department of Veterans Affairs · Perry Point, MD
Why this score
SDVOSB set-aside, 46 days to respond.
Solicitation # RFI-195000-26-00181Updated Oct 19, 2026
This RFP closed on Nov 2, 2026.
Nov 2, 2026
Responses were due Nov 2, 2026, 2:00 PM EST
Same NAICS group or Construction & Renovation, nearby first, ranked by score.
Department of Veterans Affairs · Perry Point, MD
Why this score
SDVOSB set-aside, 46 days to respond.
National Institutes of Health · Bethesda, MD
Why this score
24 days to respond, recently updated; but small typical award (~$227K).
Agricultural Research Service · Beltsville, MD
Why this score
26 days to respond, new this week; but small typical award (~$202K).
Department of the Navy · Newport, RI
Why this score
Small-business set-aside, active buyer ($18.5B FY24–FY26).
Department of Veterans Affairs · South Nasville, TN
Why this score
SDVOSB set-aside, 30 days to respond.
Department of the Navy
Why this score
Small-business set-aside, active buyer ($18.5B FY24–FY26).
RFP Detector Scores are informational.How we score →
Summary by RFP Detector
National Institute of Standards and Technology (Department of Commerce NIST), part of the Department of Commerce, posted a special notice titled “Building 215 Clean Room HEPA Filter Replacement” under solicitation number RFI-195000-26-00181. It was first posted on Sep 8, 2026 and has been updated 3 times since. The response deadline was Nov 2, 2026, 2:00 PM EST. It is classified under NAICS 236210 (Industrial Building Construction) and product/service code Z2DB. No set-aside is listed. The place of performance is Gaithersburg, Maryland. The listed point of contact is Richard Trent Stevens.
Score at publication
Every RFP starts at 50. Each factor adds or subtracts points compared with a typical RFP; unknown data counts as neutral.
Frozen at publication: closed RFPs are not re-scored.
Starts at 50
No value published. Typical award is about $189K: the median of 989 federal contracts over $25K awarded in NAICS 236210, FY24–FY26.
Full and open competition. The largest recipient took 22% of these dollars in FY24–FY26.
Across all agencies, NAICS 236210 saw 1,312 contracts worth $3.6B in FY24–FY26. No agency-specific history found. 24 other notices from this office in the past 12 months.
Special notice: 55 days to respond (due Nov 2, 2026, 2:00 PM EST).
Documents not listed, named contact with email, 2,088-word description.
Posted today.
50 + contributions = 65 (B, Strong)
Informational, not advice to bid or not bid. Score version 1.0.0, evaluated Sep 8, 2026.
Eligibility · Full and open competition
Full and open competition means the notice states no set-aside: any responsible business can respond, subject to the requirements in the notice.
Not stated in a form we could extract. See the official solicitation for requirements, evaluation criteria and submission steps.
From the official notice
The RFI response due date has been extended to November 2, 2026. The RFI response due date has been extended to October 26, 2026. Site Visit The National Institute of Standards and Technology (NIST) will conduct an optional site visit in connection with its Request for Information (RFI) for the Building 215 Cleanroom HEPA Filter Replacement requirement at the NIST Gaithersburg campus. The purpose of the visit is to help interested vendors understand the existing conditions and provide informed responses to the RFI. The visit is for market research only. Attendance is not required to respond to the RFI or to participate in any future solicitation. This site visit does not constitute a solicitation or a request for proposals or quotations. NIST will not award a contract or reimburse attendance or response costs on the basis of the RFI. RFI responses will be used for planning purposes and will be treated as information, not offers. The Government will host a site visit on Friday, October 9, 2026, at 9AM EST at the following location: National Institute of Standards and Technology 100 Bureau Drive, Building 215 Lobby Gaithersburg, MD 20899 Offerors interested in attending the site visit must submit their request for visitor badge via email to Drew.Comley@nist.gov and Warren.Livengood@nist.gov by no later than Wednesday, October 7, 2026. Offerors shall use the email subject line: Site Visit – B215 HEPA Filter RFI All requests must include the following information: Visitor’s full legal name. Visitor’s country of citizenship. NIST Gaithersburg is a secure federal facility. On the date of the site visit, all Visitors to NIST Gaithersburg may access the site, through the Visitor Center from the main gate (Gate A) at W. Diamond Ave. and Bureau Drive. All visitors must be preregistered and present photo identification and vehicle registration information upon arrival. NIST can only accept a state-issued driver’s license or identification card for access to federal facilities if issued by states that are REAL ID compliant or have an extension. For more information about visiting the NIST Gaithersburg campus, please visit https://www.nist.gov/visit. REQUEST FOR INFORMATION (RFI) BUILDING 215 ADVANCED MEASUREMENT LABORATORY (AML) CLEANROOM REPAIR AND HEPA FILTER REPLACEMENT Solicitation/Reference No.: 1333ND26RNB190014 1. PURPOSE OF THIS REQUEST FOR INFORMATION The National Institute of Standards and Technology (NIST) is conducting market research pursuant to Federal Acquisition Regulation (FAR) Part 10 and FAR 15.201 to obtain industry feedback concerning the scope, schedule, phasing, cleanroom outage requirements, technical and performance risks, and estimated construction cost associated with the Building 215 Advanced Measurement Laboratory (AML) Cleanroom Repair and HEPA Filter Replacement project. NIST previously solicited this requirement under Solicitation No. 1333ND26RNB190014. NIST did not receive an acceptable offer under that solicitation. NIST is therefore reassessing the requirement and acquisition approach before determining whether and how to resolicit the project. NIST is particularly interested in identifying aspects of the requirement that may materially affect industry participation, constructability, schedule feasibility, pricing, risk, or the ability of contractors to submit competitive proposals. Industry is encouraged to provide candid feedback and to identify recommended changes that could improve constructability, competition, schedule feasibility, cost certainty, and overall project execution while continuing to meet NIST’s mission and cleanroom operational requirements. 2. RFI / MARKET RESEARCH NOTICE THIS RFI IS ISSUED SOLELY FOR INFORMATION AND ACQUISITION PLANNING PURPOSES. IT DOES NOT CONSTITUTE A REQUEST FOR PROPOSAL (RFP), INVITATION FOR BID (IFB), REQUEST FOR QUOTATION (RFQ), OR OTHER SOLICITATION. The Government does not intend to award a contract based on responses to this RFI. Responses will be treated as information only and shall not be construed as offers or proposals that can be accepted by the Government to form a binding contract. The Government will not reimburse respondents for costs incurred in preparing or submitting information in response to this RFI or for participating in any follow-up discussions. This RFI does not obligate the Government to issue a solicitation or award a contract, nor does it restrict the Government’s ultimate acquisition approach. Respondents are advised that information submitted in response to this RFI may be used by NIST in developing or revising the acquisition strategy, statement of work, specifications, schedule, phasing requirements, outage requirements, Government cost estimate, and future solicitation. Respondents should clearly identify and mark any proprietary, confidential, or commercially sensitive information contained in their responses. Respondents should avoid including proprietary information unless necessary to provide a meaningful response. 3. PROJECT BACKGROUND The project involves repair and modernization work within the Building 215 Advanced Measurement Laboratory cleanroom located at the NIST Gaithersburg Campus. The AML cleanroom encompasses approximately 1,800 square meters and includes approximately 750 square meters of Class 100 cleanroom space. The facility supports sensitive NIST research activities and contains specialized and, in some instances, irreplaceable scientific equipment. The project generally includes, but is not limited to: Replacement of approximately 1,200 terminal supply HEPA filters; Repair and/or modification of HEPA filter connections; Testing, balancing, certification, and recertification of affected HEPA filters and cleanroom spaces; Replacement of approximately 70 variable air volume (VAV) terminal units; Replacement of approximately 54 airflow monitoring devices; Installation of approximately 32 exhaust air control valves; Modification and repair of associated ductwork; Rebalancing of associated air-handling and exhaust systems; Verification and repair, as required, of existing capped ductwork; Controls-related work; Cleaning, testing, balancing, commissioning, and cleanroom certification associated with each affected area; and Protection of existing cleanroom spaces, research operations, and sensitive scientific equipment throughout construction. Detailed project drawings, specifications, and/or relevant portions of the previously issued solicitation may be attached to this RFI or otherwise made available through (see the official solicitation) for purposes of industry review. 4. CURRENT PHASING AND OUTAGE CONCEPT NIST’s previous acquisition strategy was developed to minimize disruption to ongoing research operations by performing the work through phased cleanroom outages rather than shutting down the entire cleanroom for the duration of construction. The previous requirement contemplated 19 construction phases consisting of 18 Critical Cleanroom Outage Phases and one Non-Critical Phase. For each Critical Cleanroom Outage Phase, the contemplated outage period was approximately nine calendar days, generally structured as follows: Outage/construction activities begin at approximately 7:00 p.m. on Friday; Work proceeds continuously, including 24-hour-per-day/seven-day-per-week operations, as necessary; Construction, startup, testing, balancing, cleaning, commissioning, and applicable cleanroom certification are completed during the outage period; and The affected cleanroom area is required to achieve Ready for Re-Occupancy by approximately 7:00 a.m. on the second following Monday. Ready for Re-Occupancy generally means that required construction, startup, testing, balancing, cleaning, commissioning, and applicable cleanroom certification have been completed; the affected area is operationally capable of supporting its intended use without material restriction; and no deficiencies remain that materially impair safe occupancy or cleanroom operations. The previous requirement also contemplated maintaining unaffected cleanroom bays in operation to the maximum extent practicable and included the possibility of limited additional weekend outages affecting larger portions of the cleanroom. NIST recognizes that these operational constraints may significantly affect contractor staffing, sequencing, subcontractor availability, construction risk, pricing, and schedule feasibility. NIST is specifically seeking industry feedback concerning these requirements. 5. INFORMATION REQUESTED FROM INDUSTRY Respondents are requested to review the project information provided with this RFI and address the following topics. Respondents are not required to answer every question; however, detailed and candid responses are encouraged. A. Outage Feasibility and Constraint Identification Critical Path Bottlenecks: Identify the specific trade activities that present the highest risk to achieving a 9-day bay outage window. Realistic Outage Duration: Based on your experience in occupied nanofabrication facilities, what is a realistic, achievable calendar-day duration to complete a single cleanroom bay/module from shutdown to final recertification? Risk & Impact Analysis: Explain how the current 24-hour, 9-day limit impacts project risk, labor density, safety, quality assurance, and total cost (including risk contingencies for $8,000/day liquidated damages). Phasing & Mock-Up Alternatives: Would executing a "mock-up bay" or initial trial phase establish a viable baseline for subsequent production bays? B. Construction Cost Estimate Based on the information provided, what is industry’s rough-order-of-magnitude (ROM) estimated construction cost for the complete project? Respondents may provide either a specific estimated amount or a reasonable estimated range. To the extent practicable, please identify the approximate portion of the ROM estimate attributable to: Direct construction work; HVAC/HEPA/VAV work; Controls work; Testing and balancing; Commissioning and cleanroom certification; Premium time, shift work, or 24/7 outage staffing; General conditions; Phasing and temporary protection; Contingency/risk allowance; and Other significant cost drivers. Approximately what percentage or dollar amount of the estimated construction cost is attributable specifically to the current nine-day phased-outage approach? If NIST modified the outage durations or phasing strategy, what approximate cost reduction or increase would industry anticipate? ROM estimates submitted in response to this RFI are requested solely for market research and acquisition planning. They will not constitute offers, proposals, bids, quotations, or binding commitments. C. Experience Working in an occupied Nano-Fab Cleanroom The previous solicitation included Evaluation Factor #2 which required that the contractor have completed a minimum of two (2) HEPA Filter replacements in an occupied laboratory within the previous six years. Based on your experience in occupied nanofabrication facilities, is this a realistic and practical requirement? D. Competition and Industry Participation Based on the project as currently structured, would your company consider submitting a proposal if NIST resolicits this requirement? Yes / No / Possibly Please explain the primary factors influencing your answer. What aspects of the previous/current requirement would discourage your company or other qualified contractors from submitting a proposal? Are the project’s size, bonding requirements, insurance requirements, cleanroom experience requirements, key personnel requirements, outage schedule, liquidated damages, fixed-price structure, or other contractual requirements likely to limit competition? What changes, if any, would materially increase the likelihood that qualified contractors would compete for this project? What type of contractor and subcontractor experience should NIST reasonably require without unnecessarily restricting competition? E. Additional Industry Feedback Please identify any requirement, specification, schedule constraint, contract term, risk allocation, or other issue not addressed above that NIST should consider before resoliciting this project. Please provide any additional recommendations that could improve competition, constructability, schedule reliability, cost certainty, or successful project execution. 6. RESPONDENT INFORMATION Respondents are requested to provide the following: Company name; Company address; Name, title, telephone number, and email address of the point of contact; Unique Entity ID (UEI), if available; Business size and socioeconomic status under the anticipated NAICS code; Relevant experience performing comparable cleanroom, laboratory, HVAC, HEPA filtration, controls, testing/balancing, or phased occupied-facility construction; Whether the respondent would anticipate performing as a prime contractor or subcontractor; and Whether the respondent would be interested in participating in a future industry day, one-on-one market research meeting, or site visit concerning this requirement. 7. RESPONSE INSTRUCTIONS Responses should be submitted electronically to Richard.stevens@nist.gov and Drew.Comley@nist.gov no later than October 14, 2026. The subject line should state: RFI Response – 1333ND26RNB190014 – Building 215 AML Cleanroom Project NIST recommends but does not require that responses be limited to approximately 10-pages, excluding supporting documentation. Respondents may provide responses in Microsoft Word or searchable PDF format. NIST may contact individual respondents for clarification or additional market research discussions. Participation in this RFI or any subsequent market research activity is voluntary and will not affect a firm’s ability to compete for any future solicitation. Respondents should clearly mark proprietary or confidential business information. NIST requests that respondents also provide, where practicable, a version of their response from which proprietary information has been redacted if the response contains significant proprietary material. 8. GOVERNMENT USE OF RESPONSES Information obtained through this RFI may be used by NIST to develop or revise the acquisition strategy, Government estimate, specifications, statement of work, construction phasing, outage durations, schedule, contract structure, solicitation terms, and other acquisition documents. NIST may summarize industry responses for internal Government planning purposes. NIST does not intend to publicly identify individual respondents’ proprietary business information or attribute proprietary recommendations to a particular respondent. The Government may incorporate concepts, recommendations, or approaches identified through market research into a future solicitation, provided such use is consistent with applicable law, regulation, and protection of proprietary information. 9. FAR 52.215-3 – REQUEST FOR INFORMATION OR SOLICITATION FOR PLANNING PURPOSES FAR 52.215-3, Request for Information or Solicitation for Planning Purposes, is incorporated into this notice. For purposes of paragraph (c) of FAR 52.215-3, this RFI is issued for the purpose of obtaining industry information concerning the feasibility, constructability, schedule, cleanroom outage requirements, risk allocation, acquisition approach, and estimated construction cost for the Building 215 AML Cleanroom Repair and HEPA Filter Replacement project to support NIST’s acquisition planning and potential resolicitation of the requirement. END OF REQUEST FOR INFORMATION
No documents are listed for this notice.
Richard Trent Stevens
PrimaryPoints of contact as published on the notice.
1 change since posting.
Special Notice posted
Special Notice posted
Special Notice posted
Special Notice posted
Responses were due
Status changed to archived
Federal award history
All agencies · NAICS 236210 · FY24–FY26
Recipients of past awards in this market, not the incumbent of this RFP.
| Fiscal year | Obligated ($) |
|---|---|
| FY2022 | 612,007,392.04 |
| FY2023 | 1,106,971,355.86 |
| FY2024 | 1,533,349,396.76 |
| FY2025 | 1,177,804,059.53 |
| FY2026 | 926,999,952.23 |
Federal contract award records, award types A–D, FY24–FY26. Updated Nov 15, 2026.
6 open RFPs from this issuer and its offices.
National Institute of Standards and Technology · Gaithersburg, MD
Why this score
But only 2 days left.
National Institute of Standards and Technology · Gaithersburg, MD
Why this score
New this week, clear, complete notice; but small typical award (~$60K).
National Institute of Standards and Technology · Gaithersburg, MD
Why this score
Clear, complete notice, full and open; but small typical award (~$83K).
National Institute of Standards and Technology · Gaithersburg, MD
Why this score
13 days to respond, full and open; but small typical award (~$83K).
National Institute of Standards and Technology · Gaithersburg, MD
Why this score
14 days to respond, full and open; but small typical award (~$83K).
National Institute of Standards and Technology · Boulder, CO
Why this score
New this week, 19 days to respond; but small typical award (~$100K).
RFP Detector Scores are informational.How we score →
Official federal notice. Updated Oct 19, 2026.
Official solicitation:Sign in free to open the official solicitation
RFP Detector is an independent service and is not affiliated with any government agency. Scores are informational.
RFP Detector is not affiliated with the organization that issued this RFP. Always rely on the official notice and confirm every date and requirement with the issuer.