Hydraulic Actuator Flow Test Stand
Department of the Navy · San Diego, CA
Why this score
Active buyer ($15.8B FY24–FY26), new this week; but small typical award (~$193K).
Solicitation # SLAC_369019_DCPowerSupplyUpdated Nov 19, 2026Scored Nov 20, 2026
Nov 30
Nov 30, 2026, 5:00 PM PST
Summary by RFP Detector
Department of Energy (Slac Natl Accel Lab -Doe Contractor) posted a solicitation titled “DC Power Supply” under solicitation number SLAC_369019_DCPowerSupply. It was first posted on Nov 19, 2026 and has been updated once since. Responses are due Nov 30, 2026, 5:00 PM PST. It is classified under NAICS 3333 (Commercial and Service Industry Machinery Manufacturing) and product/service code AJ12. No set-aside is listed. The place of performance is Menlo Park, California. The listed point of contact is Katherine Jill A. Coh.
RFP Detector Score
Every RFP starts at 50. Each factor adds or subtracts points compared with a typical RFP; unknown data counts as neutral.
Starts at 50
No value published, and there isn't enough award history to estimate one. Scored as neutral.
Full and open competition.
6 other RFPs from Department of Energy on RFP Detector in the past 12 months; no award history found.
Solicitation, bids due: 11 days to respond (due Nov 30, 2026, 5:00 PM PST).
Documents not listed, named contact with email and phone, 886-word description.
Posted today.
50 + contributions = 66 (B, Strong)
Informational, not advice to bid or not bid. Score version 1.0.0, evaluated Nov 20, 2026.
Eligibility · Full and open competition
Full and open competition means the notice states no set-aside: any responsible business can respond, subject to the requirements in the notice.
Not stated in a form we could extract. See the official solicitation for requirements, evaluation criteria and submission steps.
From the official notice
SLAC National Accelerator Laboratory is operated by Stanford University for the Department of Energy. As a management and operating contractor, subcontracts awarded by the Laboratory are not Federal procurements, and are not directly subject to the Federal Acquisition Regulations in 48 CFR. Nonetheless, certain Federal laws, Executive Orders, and regulations may affect our DOE approved purchasing system, as required by statute, regulation, or contract terms and conditions. Please review the requirements and provide your best and final offer for both price and lead-time. The following has been attached for you to complete and review: (BAA) Buy American Act Certification Representations & Certifications Rider Confirm attached SLAC Terms and Conditions are accepted Technical Specifications Requested for Quote: Modular, remotely controllable DC power supply system for detector electronics Quantity: 1 EA Please provide a price and lead time quotation by Monday, November 30, 2026. Technical Evaluation Factors Listed Below: Ability to Meet the Technical Requirements: The Offeror’s proposal and supporting technical documentation will be evaluated to confirm compliance with the required detector power-supply specifications listed below. Schedule and Delivery Date: The University will evaluate the proposed lead time and delivery schedule against SLAC’s required project schedule. An acceptable lead time is within 30 weeks after issuance of the purchase order. Past Performance: The University may evaluate documentation demonstrating prior manufacturing and delivery of similar or comparable equipment. Offerors with no relevant past or present performance history may receive an “Unknown Confidence” rating. Required item(s) are listed below: Modular, remotely controllable DC power supply system for detector electronics Quantity: 1 EA Technical Requirements: Provide stable, low-noise, programmable DC power over at least the 30–60 VDC range. Support detector loads requiring up to 13.5 A and approximately 650 W per required output or load group. Support multiple independently controllable outputs, with the final number of outputs determined by the detector configuration and support for up to 16 outputs where applicable. Outputs shall be electrically isolated/potential-free where required by the detector grounding scheme. Provide programmable voltage and current limits, ramp rates, trip thresholds, temperature protection, and configurable fault behavior, including individual-channel and grouped-channel shutdown where needed to protect detector electronics. Output noise and ripple shall be sufficiently low for sensitive detector operation. Vendors shall provide guaranteed ripple and noise specifications with measurement conditions. Ethernet-based remote monitoring and control are required, including readback of voltage, current, status, fault state, and temperature or over-temperature status. A local service/configuration interface is required. Web interface and SNMP support are specifically required for SLAC controls integration. The system shall be air-cooled, protected against over-temperature conditions, and suitable for continuous operation at rated load in the intended SLAC installation environment. Operate from SLAC-compatible AC mains power, nominally 100–240 VAC, 50/60 Hz, with appropriate power factor correction and compliance with applicable electrical safety and EMC standards. The system shall be compatible with standard SLAC rack or detector support installations. Standard 19-inch rack mounting is required if installed in existing SLAC racks. A compact form factor, such as 3U height or less and approximately 450 mm depth or less, is preferred unless the final installation envelope requires these limits. Vendors shall provide mechanical dimensions, weight, cooling requirements, power input requirements, output connector details, isolation ratings, safety certifications, and remote-control interface documentation. Redundant output capability, master-slave or parallel operation for current boosting, extended floating voltage capability, browser-based configuration, SNMP support, and modular field-serviceable architecture are required by the detector configuration. Source Selection: Source selection will be conducted using the Lowest Price Technically Acceptable (LPTA) method. Award will be made to the responsible Offeror submitting the lowest-priced offer that is determined technically acceptable in accordance with the stated evaluation factors. Please provide a price and lead time quotation by Monday, November 30, 2026. Is there any room for additional discount such as for Academic, ICPT, GSA, or Government Institutions? Buy American Act Certification (BAA) applies as applicable to this procurement. Representations & Certifications Rider is required. Once completed, the Reps and Certs is valid for one year until renewal. If you have already completed one within the year, please disregard. Otherwise, please complete and return. Please include in your proposal the Harmonized Tariff Schedule (HTS Code) and Export Control Classification Number (ECCN), if applicable. Please identify any applicable tariffs, duties, or other import-related charges as separate line items in your quotation. All subcontractors are required to register in the System for Award Management ((see the official solicitation)). If possible, please provide a link to your webpage for a published price list or other information to substantiate the prices quoted. The resulting purchase order will be issued on a fixed-price basis. SLAC National Accelerator Laboratory Terms and Conditions for Fixed Price Commercial Supplies and Services, as well as any applicable supplemental rider, will be made a part of the resulting order. Please markup the terms and conditions if you wish to negotiate. No markups mean that you accept SLAC Terms and Conditions. Payment Terms will be NET-30. Domestic Suppliers: Freight terms will be FOB Destination Prepaid and Add. Foreign Suppliers: Shipment will be made CIP SLAC, Menlo Park, and Duty Unpaid. You are requested to mark and identify proprietary/confidential information provided in response to the solicitation. Please submit your quotation by Monday, November 30, 2026. Contact me directly with any questions. Ashli Gibson | Procurement Commodities Team BSD Supply Chain Management P: 650-926-3167 E: ashlig@slac.stanford.edu
No documents are listed for this notice.
Katherine Jill A. Coh
PrimaryPoints of contact as published on the notice.
Solicitation posted
Solicitation posted
Responses dueNext · in 10 days
Archive date on the official notice
Same NAICS group or Supplies, Equipment & Furniture, nearby first, ranked by score.
Department of the Navy · San Diego, CA
Why this score
Active buyer ($15.8B FY24–FY26), new this week; but small typical award (~$193K).
Department of Veterans Affairs · Mather, CA
Why this score
VOSB set-aside, new this week; but small typical award (~$114K).
Department of Energy · California
Why this score
50 days to respond, new this week; but small typical award (~$107K).
Department of the Navy · San Diego, CA
Why this score
61 days to respond, recently updated.
Defense Logistics Agency · California
Why this score
Active buyer ($11.7B FY24–FY26), new this week; but small typical award (~$67K).
Department of the Navy · San Diego, CA
Why this score
Active buyer ($27.3B FY24–FY26), new this week.
RFP Detector Scores are informational.How we score →
129 open RFPs from this issuer and its offices.
Department of Energy
Why this score
Posted today; but only 3 days left.
Department of Energy · Oak Ridge, TN
Why this score
New this week, active market ($440M FY24–FY26); but only 4 days left.
Department of Energy · New York
Why this score
Recently updated, clear, complete notice; but small typical award (~$39K).
Why this score
Recently updated, active issuer (26 RFPs); but only 4 days left.
Why this score
New this week; but small typical award (~$93K).
Department of Energy
Why this score
Small-business set-aside, posted 9 days ago; but limited award history ($2.5M FY24–FY26).
RFP Detector Scores are informational.How we score →
Official federal notice. Updated Nov 19, 2026.
Official solicitation:Sign in free to open the official solicitation
RFP Detector is an independent service and is not affiliated with any government agency. Scores are informational.
RFP Detector is not affiliated with the organization that issued this RFP. Always rely on the official notice and confirm every date and requirement with the issuer.