What this RFP is about

Department of Veterans Affairs (PCAC (36C776)) posted a sources sought notice titled “FY27 NRM - EHRM Base 573-27-702-DB EHRM Generator Upgrades Design-Build - Gainesville VAMC” under solicitation number 36C77627Q0073. It was posted on Nov 23, 2026. Responses are due Dec 7, 2026, 2:00 PM EST. It is classified under NAICS 238210 (Electrical Contractors and Other Wiring Installation Contractors) and product/service code Y1DA. No set-aside is listed. The place of performance is Gainesville, Florida. The listed point of contact is Shawn Tavernia, Contract Specialist.

Key facts

Sector
Federal
Notice type
Sources sought
As posted: Sources Sought
PSC
Y1DA
Place of performance
Gainesville, FL
ZIP 32608
Value
Not statedTypical award in this market ≈ $123.5K
Solicitation #
36C77627Q0073
Listing
Official federal notice

RFP Detector Score

Score breakdown

Every RFP starts at 50. Each factor adds or subtracts points compared with a typical RFP; unknown data counts as neutral.

Starts at 50

  • Value−6.7estimated

    No value published. Typical award is about $124K: the median of 447 VA contracts over $25K awarded in NAICS 238210, FY24–FY26.

  • Competition & access+5.9measured

    Full and open competition. The largest recipient took 6% of these dollars in FY24–FY26, and spending is spread across many vendors.

  • Issuer & market+3.8measured

    VA obligated $323M on NAICS 238210 across 645 contracts in FY24–FY26. 77 other notices from this office in the past 12 months.

  • Time & stage+5.4measured

    Sources sought (market research, not a bid): 13 days to respond (due Dec 7, 2026, 2:00 PM EST).

  • Clarity & completeness+5.0estimated

    Documents not listed, named contact with email and phone, 1,213-word description.

  • Freshness+9.0measured

    Posted today.

50 + contributions = 72 (B, Strong)

Informational, not advice to bid or not bid. Score version 1.0.0, evaluated Nov 24, 2026.

Requirements & submission

Eligibility · Full and open competition

Full and open competition means the notice states no set-aside: any responsible business can respond, subject to the requirements in the notice.

Not stated in a form we could extract. See the official solicitation for requirements, evaluation criteria and submission steps.

From the official notice

Description

1,213 words

SYNOPSIS: INTRODUCTION: This Sources Sought Notice is for market research and information purposes only at this time and shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs (VA). The VA Office of Facilities Acquisition (OFA), Program Contracting Activity Center (PCAC) is conducting market research to identify qualified sources capable of performing a Design-Build (DB) project. Services to include Architect and Engineering (DB A/E) design services, site preparation and DB Construction (DB C) services for the construction of Emergency Power Generator Upgrade for Electronic Health Record Modernization at the Malcom Randall VA Medical Center (VAMC) located in Gainesville, Florida. PROJECT DESCRIPTION: The Malcom Randall VA Medical Center (Gainesville VAMC) has a requirement to design and construct an Emergency Power Generator Upgrade to support Electronic Health Record Modernization (EHRM) at the Malcom Randall VA Medical Center. This Design-Build Team (DBT) shall provide all design and construction services, investigations, labor, materials, equipment, supervision, transportation, permits, temporary emergency power, demolition, lawful disposal, site improvements, testing, commissioning, training, and documentation necessary to deliver a complete turnkey Emergency Power Generator Upgrade for EHRM at MRVAMC. The DBT shall evaluate existing conditions and deliver a code-compliant operational emergency power system while protecting the existing Emergency Power Switchboard and maintaining required hospital emergency power capability throughout construction, subject only to specifically approved planned switching windows. The facility's existing 1,275 kW emergency generator (Generator #5) reportedly operates at approximately 85% load; the Contractor shall independently verify actual demand and operating conditions. Planned EHRM infrastructure is estimated to add 150-200 kW of critical load, including IDF/telecommunications closets and associated cooling; the Hybrid OR project is estimated to add approximately 100 kW of emergency loads. These figures are planning estimates, not verified design loads. The replacement generator shall be rated at not less than 2,000 kW and selected to provide at least 10% unused rated kW capacity after accounting for verified coincident operating demand, planned loads, and site derating. The DBT shall provide a complete enclosed generator and all required fuel, exhaust, switchgear interface, ATS, distribution, monitoring, platform, site, and temporary emergency power work. Existing generator site boundaries are constrained; significant expansion to the north or south is not anticipated to be feasible. The DBT shall confirm the usable footprint and design a solution accordingly. PROCUREMENT INFORMATION: The proposed project will be a competitive, firm-fixed-price contract utilizing the design-build approach outlined in Revolutionary FAR Overhaul (RFO) 36.101-2, Use of two-phase design-build selection procedures. The results and analysis of the market research will finalize the determination of the procurement method. The type of socio-economic set-aside, if any, will depend upon the responses to this notice and any other information gathered during the market research process. This project is planned for advertising in mid-January 2026. The Magnitude of Construction for this project is between $5,000.000.00 and $10,000,000.00. The North American Industry Classification System (NAICS) code 238210 (size standard $19.0 million) applies to this procurement. The duration of the project is currently estimated at 730 calendar days from the issuance of a Notice to Proceed. The services for this project will include providing all design and construction related services. CAPABILITY STATEMENT: Respondents shall provide a general capabilities statement to include the following information: Section 1: Provide company name, DUNS number and Unique Entity Identifier (UEI), company address, Point-of-Contact name, phone number and email. Section 2: Provide company business size based on NAICS code 238210. Also, provide business type (i.e., Large Business, Small Business, Service-Disabled Veteran Owned Small Business, Small Disadvantaged Business, Women-Owned Small Business, Hub Zone Small Business, etc.). Section 3: Provide a statement of interest in the project. Section 4: Provide the prime contractor s available bonding capacity in the form of a letter of intent from your bonding company with this submission. *Please ensure that the individual bonding capacity is in line with the VAPM Magnitude of Construction listed above. Section 5: Provide the type of work your company has performed in the past in support of the same or similar requirement. This section is IMPORTANT as it will help to determine the type of socio-economic set-aside, if any. Please provide the following in your response: Provide a maximum of three (3) projects completed within the last ten years (10) years in which the Offeror s design-build team has worked together on previous design-build contracts similar in size, magnitude, complexity, and scope to this project. Projects must demonstrate a respondent s design-build experience as a prime construction contractor directly responsible to the owner and managing multiple subcontractors. NOTE: If a prime contractor does not have Design-Build experience, they are permitted to provide up to three (3) relevant non-Design-Build projects that are completed in clinical, hospital or other medical related use space similar in size, magnitude, complexity, and scope to this project. The designer for the team may also provide up to three (3) relevant projects that fall under the requested criteria for the project. A maximum total of six (6) projects may be submitted between the D-B and design teams. *All submission requirements for these projects remain the same and are listed above. Describe your Self-Performed** effort (as either a Prime or Subcontractor). Describe Self-Performed work in terms of dollar value and description. **Self-Performed means work performed by the offeror themselves, NOT work performed by another company for them for any of the project examples provided. It is requested that interested contractors submit a response (electronic submission) of no more than twelve (12) single sided pages, single-spaced, 12-point font minimum that addresses the above information. This response must be submitted as a single application-generated (not scanned) PDF document that is less than or equal to 4MB in size. Please note that hard copies will not be accepted. Please also include a cover page, which includes, at a minimum: the company s name, address, Unique Entity Identifier (if available), socio-economic status, point-of-contact name, phone number, and e-mail address. Responses must include the Sources Sought number and project title in the subject line of their e-mail response. Submissions (responses) shall be submitted via email to the primary and secondary points of contact listed below by December 7, 2026, at 2:00 PM ET. No phone calls will be accepted. The Capabilities Statement submitted in response to this Sources Sought shall not be considered to be a bid or proposal. This notice is for information and planning purposes only and is neither to be construed as a commitment by the Government nor will the Government pay for information solicited. No evaluation letters and/or results will be issued to the respondents. After completing its analyses, the Government will determine whether to limit competition among the small business categories listed above or proceed with full and open competition as other than small business. At this time no solicitation exists; therefore, please do not request a copy of the solicitation. If a solicitation is released it will be synopsized in Contract Opportunities at (see the official solicitation). It is the potential offeror's responsibility to monitor this site for the release of any solicitation or synopsis. Please respond to both points of contact. Contracting Office Address: Office of Facilities Acquisition (OFA) Program Contracting Activity Center (OFA PCAC) 6100 Oak Tree Blvd. Suite 490 Independence, OH 44131 Primary Point of Contact: Shawn Tavernia Contract Specialist Shawn.Tavernia@va.gov

Documents

No documents are listed for this notice.

Contacts

Points of contact as published on the notice.

Timeline & history

  1. Sources Sought posted

  2. Responses dueNext · in 13 days

  3. Archive date on the official notice

Federal award history

Market context

Department of Veterans Affairs · NAICS 238210 · FY24–FY26

Typical award (over $25K)
$123.5K
Contracts awarded
645
Total obligated
$322.5M
Award size, Department of Veterans Affairs · NAICS 238210 contracts, FY24–FY26 (log scale)
P25 $19.5KMedian $68.3KP75 $203.8KP90 $678.3K

Largest recipients in this market

  • J & J MECHANICAL AND CONSTRUCTION GROUP LLC$19.3M6%
  • SKYTEK LLC$18.7M6%
  • STANDARD COMMUNICATIONS INC$15.6M5%

Recipients of past awards in this market, not the incumbent of this RFP.

View as table
Fiscal yearObligated ($)
FY2022136,512,915.97
FY202395,845,020.31
FY202476,515,759.88
FY202587,762,744.24
FY2026158,259,822.85

Federal contract award records, award types A–D, FY24–FY26. Updated Nov 13, 2026.

Similar open RFPs

Same NAICS group or Construction & Renovation, nearby first, ranked by score.

Strong

Chiller Preventative Maintenance Services

Department of Veterans Affairs · Florida

FederalCombined synopsisSDVOSB set-asideConstruction & Renovation+1
Posted Nov 17Due Dec 3, 2026, 12:00 PM EST (in 9 days)Federal notice
Limited

Replace Elevators at FDC Miami

Federal Prison System / Bureau of Prisons · Miami, FL

FederalPresolicitationSmall business set-asideConstruction & Renovation+1
Posted Sep 28Due Dec 3, 2026, 1:00 PM EST (in 9 days)Federal notice
Excellent

FY27 NRM (PROJ 573-24-110) BB - Expand Cardiology Service

Department of Veterans Affairs · Gainesville, FL

FederalSpecial noticeSDVOSB set-asideConstruction & Renovation+1
Posted Nov 17Due Dec 18, 2026, 3:30 PM EST (in 24 days)Federal notice

RFP Detector Scores are informational.How we score →

More from Department of Veterans Affairs

440 open RFPs from this issuer and its offices.

Strong

612A4-27-018 | Replace B650 3rd and 2nd Flooring

Department of Veterans Affairs · Mather, CA

FederalSolicitationSDVOSB set-asideConstruction & Renovation+1
Posted Oct 14Due Nov 24, 2026, 12:00 PM PST (in < 1 h)Federal notice
Fair

Water Treatment Services

Department of Veterans Affairs · Los Angeles, CA

FederalSolicitationSDVOSB set-asideConstruction & Renovation+1
Posted Nov 16Due Nov 24, 2026, 1:00 PM PST (in 1 h)Federal notice

RFP Detector Scores are informational.How we score →

About this notice

Official federal notice. Updated Nov 23, 2026.

Official solicitation:Sign in free to open the official solicitation

RFP Detector is an independent service and is not affiliated with any government agency. Scores are informational.

RFP Detector is not affiliated with the organization that issued this RFP. Always rely on the official notice and confirm every date and requirement with the issuer.