Fix Legionella Deficiencies Construction 676-22-101
Department of Veterans Affairs · Tomah, WI
Why this score
SDVOSB set-aside, 56 days to respond; but small typical award (~$102K).
Solicitation # W912P627X1CZ7Updated Nov 24, 2026Scored Nov 25, 2026
Dec 7
Dec 7, 2026, 2:00 PM CST
Summary by RFP Detector
Department of the Army (W072 ENDIST CHICAGO), part of the Department of Defense, posted a sources sought notice titled “Market Survey Sources Sought Notice for Barrier Iib Ats Systems Replacement” under solicitation number W912P627X1CZ7. It was posted on Nov 24, 2026. Responses are due Dec 7, 2026, 2:00 PM CST. It is classified under NAICS 238210 (Electrical Contractors and Other Wiring Installation Contractors) and product/service code Z2BG. No set-aside is listed. The listed point of contact is Stephanie Boyd.
RFP Detector Score
Every RFP starts at 50. Each factor adds or subtracts points compared with a typical RFP; unknown data counts as neutral.
Starts at 50
No value published. Typical award is about $122K: the median of 457 Army contracts over $25K awarded in NAICS 238210, FY24–FY26.
Full and open competition. The largest recipient took 11% of these dollars in FY24–FY26, and spending is spread across many vendors.
Army obligated $376M on NAICS 238210 across 651 contracts in FY24–FY26. 113 other notices from this office in the past 12 months.
Sources sought (market research, not a bid): 12 days to respond (due Dec 7, 2026, 2:00 PM CST).
Documents not listed, named contact with email and phone, 1,377-word description.
Posted today.
50 + contributions = 69 (B, Strong)
Informational, not advice to bid or not bid. Score version 1.0.0, evaluated Nov 25, 2026.
Eligibility · Full and open competition
Full and open competition means the notice states no set-aside: any responsible business can respond, subject to the requirements in the notice.
Not stated in a form we could extract. See the official solicitation for requirements, evaluation criteria and submission steps.
From the official notice
SOURCES SOUGHT NOTICE / MARKET SURVEY Project Title: Barrier IIB Automatic Transfer Switch (ATS) System Replacement************** Procurement Identification: PANGLR -26 -034692**************NAICS Code: 238210 Electrical Contractors and Other Wiring Installation Contractors (Small Business Size Standard: $19.0 Million)**************PSC Code: Z2BG Repair or Alteration of Electronic and Communications Facilities**************Estimated Project Magnitude / Cost: Between $250,000 and $500,000************** Primary Performance Location: Chicago Sanitary and Ship Canal Electric Dispersal Barrier Facility (USGS / USACE Facility), 790 East Old Romeo Rd., Lockport/Romeoville, IL 60441*****************By way of this Market Survey/Sources Sought Notice, the USACE-Chicago District intends to determine the extent of firms that are engaged in providing the services described hereunder for the Barrier IIB Automatic Transfer Switch (ATS) System Replacement. The responses to this Notice will be used for planning purposes for an upcoming procurement. Therefore, this Notice does not constitute a Request for Proposal (RFP); it does not guarantee the future issue of an RFP; nor does it commit the government to contract for any supply or service whatsoever. Further, this Agency will not accept unsolicited proposals. Respondents are advised that this Agency will not pay for any information or administrative cost incurred in response to this Notice; all costs associated with responding to this Notice will be solely at the responding party expense.***************t this time, proprietary information is not being requested, and respondents shall refrain from providing proprietary information in response to this Notice. Responses to this Notice will not be returned. Please be advised that all submissions become Government property and will not be returned. Not responding to this Notice does not preclude participation in any future RFQ. Responses to this notice are not offers and cannot be accepted by the U.S Government to form a binding contract. It is the responsibility of the interested parties to monitor this site for additional information pertaining to this Notice.*******GOVERNMENT REQUIREMENTS Under the proposed contract, the contractor will be required to provide turnkey engineering, procurement, programming, fabrication, removal, installation, testing, and commissioning services for the controls modernization of the Barrier IIB Automatic Transfer Switch (ATS) and Emergency Generator Paralleling Switchgear line-up (originally installed circa 2010).*********Scope Summary:************The project requires the complete replacement and modernization of obsolete proprietary electronic control modules, network processors, transducers, and human-machine interface (HMI) touchscreens with modern, open-architecture, commercial-off-the-shelf (COTS) industrial control components.************The contractor shall provide a complete, non-proprietary functional solution meeting the following performance characteristics without relying on single-source, dealer-locked software or hardware:**************1. Master, Utility, Tie, and Generator Control Processors:************Furnish and program modular, open-architecture Programmable Logic Controllers (PLCs) or purpose-built Digital Generator Paralleling Controllers with industrial Ethernet communications.************** Provide dedicated processing hardware for:************* Master Switchgear Control (redundant processors AP1 and AP2)******** Generator Breaker Controls (dedicated controller per generator breaker)**********Utility Incoming Breaker Control (dedicated controller per utility breaker)*********Tie Breaker Control (dedicated controller per tie breaker)**********The control logic must automatically perform utility sensing, automatic transfer, generator start sequencing, dead-bus closing, auto-synchronization, isochronous kW and kVAR load sharing, soft-load open/closed-transition utility return, and load shed/add management.*********Programming must utilize non-proprietary, standard industrial software (e.g., standard IEC 61131-3 logic platforms).**************2. Power Sensing and Synchronization:********* Supply and install modern digital multi-function power transducers and automatic synchronizer / sync-check relays (Device 25) for each generator breaker, tie breaker, and utility source.*************3. Operator Interface (HMI) Visualization:***********Supply and install an industrial widescreen touchscreen display panel (minimum 15-inch diagonal) and dedicated processor running an industrial operating system.************The HMI software must display dynamic animated single-line electrical diagrams, breaker metering and status, alarm logging and management, mode selection (Auto/Manual/Test), and system diagnostics.***********Interface drivers must communicate natively via standard industrial protocols (Ethernet/IP, Modbus TCP, PROFINET, or OPC UA).**************4. Network and Communications:*********Furnish industrial managed Ethernet switches configured in a fault-tolerant ring communications architecture (replacing obsolete serial/proprietary network topologies).***********Provide protocol data gateways where necessary to output system data points (Modbus RTU/TCP or BACnet/Ethernet) to site supervisory networks.**************5. Simulation and Pre-Testing:***********All PLC and HMI programming must be factory bench-tested and verified using a static simulator reproducing the site sequence of operations prior to mobilization.**************6. On-Site Installation, Commissioning, and Constraints:************Perform on-site removal of legacy controllers, field wiring, mounting, terminations, calibrations, engine startup assistance, and full-load validation.************* Outage Limitation: On-site replacement and cutover must be accomplished within an aggressive coordinated window (estimated up to six (6) consecutive calendar days).************Life-Safety Operational Continuity: The Chicago Dispersal Barrier operates 24/7. During modernization, the emergency power system must remain functional such that at least one (1) emergency generator is continuously capable of automatic operation or rapid manual start to back up the site load.*************Deliver updated CAD as-built production drawings, sequence of operations manuals, bill of materials, component data sheets, and comprehensive on-site operator training.**********Estimated Period of Performance:********* Pre-engineering, hardware procurement, programming, and simulation testing: Ninety (90) to One Hundred Twenty (120) calendar days from Notice to Proceed (NTP).**************On-site physical installation, cutover, testing, and training: Up to six (6) consecutive calendar days.**********REQUESTED INFORMATIONAL interested Small Businesses, certified HUBZone, 8(a), Women-Owned Small Businesses (WOSB), or Service-Disabled Veteran-Owned Small Businesses (SDVOSB) should respond to this market survey/sources sought via email no via email no later than December 7, 2026, at 2:00 p.m. Central Time.*************The following requests are designed to apprise the U.S. Army Corps of Engineers, Chicago District, of any prospective small business with industrial electrical switchgear, automatic transfer switch (ATS), and PLC control integration capabilities. This Agency requests that interested contractors submit the following:**************7. Company Profile Small Business Status:******* Company name, physical address, website, and primary point of contact (name, title, telephone number, and email address.*******Contractors Unique Entity Identifier (UEI) and CAGE Code.*********** In consideration of North American Industry Classification System (NAICS) code 238210 with a small business size standard of $19.0 Million, which of the following small business categories is your business classified under, if any Small Business****Service-Disabled Veteran-Owned Small Business (SDVOSB)********* Small Disadvantaged Business (SDB)******* 8(a) Small Business********Woman-Owned Small Business (WOSB)**********Economically Disadvantaged Woman-Owned Small Business (EDWOSB)*********HUBZone Small Business******8.Technical Capability Solution Narrative:*********A brief description of your firm capability to provide the required engineering, PLC/HMI programming, cabinet wiring, and on-site commissioning.*******Identify the non-proprietary, open-architecture control platform(s) your firm is qualified to install and program (e.g., Rockwell Automation / Allen-Bradley, Schneider Electric, Woodward, DEIF, Siemens, Schweitzer Engineering Laboratories [SEL], or equal).******* Confirmation of capability to complete on-site cutover within an accelerated outage window (up to six consecutive calendar days) while maintaining continuous emergency backup power readiness.**************9. Descriptions of Experience (Past Performance):******** Interested firms must provide no more than three (3) example projects completed in the past five (5) years where the interested firm served as the prime contractor or specialized electrical/controls subcontractor on projects of similar size, scope, and complexity (e.g., industrial switchgear modernization, ATS replacement, generator paralleling controls, or SCADA/PLC retrofits).********* Each project must include the name, title, project role, email address, and telephone number of at least one reference. References may be used to verify project size, scope, dollar value, and quality of performance.******** Based on the information above, for each project submitted, include:**********Current percentage of work complete and date when it was or will be completed.********** Scope and narrative of the project (specifically detailing PLC/controls and switchgear work).******The dollar value of the contract.******** The percentage of work that was self-performed by your firms own personnel.*******Geographic location of the project.**************10. Limitations on Subcontracting Compliance:*******Small Businesses are reminded of the requirements of FAR 52.219-14 (Limitations on Subcontracting). For specialty trade / service contracts under NAICS 238210, the concern will perform at least 25% of the cost of the contract performance incurred for personnel with its own employees or employees of other similarly situated entities.******* Include a brief statement confirming how your firm will meet or exceed this self-performance requirement.********** The government will evaluate this information in shaping it**********s requirement and making a set aside determination. ************** SUBMISSION OF RESPONSES******* Page Limit: The total submittal package shall be no longer than five (5) pages. Please only include a narrative addressing the requested information; extraneous marketing collateral will not be reviewed.****** File Size Constraint: Electronic files sent via email CANNOT EXCEED 20MB (including email body and attachments); files exceeding this size will be rejected by the Government email server.**********Submission Deadline: Interested respondents shall provide their submittal package no later than December 7, 2026, at 2:00 p.m. Central Time.*********Submit To: Stephanie Boyd**************U.S. Army Corps of Engineers********* Chicago District Email: Stephanie.L.Boyd@usace.army.mil**************Ensure the Subject Line includes: Response to Sources Sought Notice: Barrier IIB ATS System Replacement PANGLR -26 -034692**************
No documents are listed for this notice.
Stephanie Boyd
PrimaryPoints of contact as published on the notice.
Sources Sought posted
Responses dueNext · in 11 days
Archive date on the official notice
Federal award history
Department of the Army · NAICS 238210 · FY24–FY26
Recipients of past awards in this market, not the incumbent of this RFP.
| Fiscal year | Obligated ($) |
|---|---|
| FY2022 | 186,368,216.97 |
| FY2023 | 220,912,486.29 |
| FY2024 | 117,026,639.32 |
| FY2025 | 147,802,016.9 |
| FY2026 | 111,529,503.01 |
Federal contract award records, award types A–D, FY24–FY26. Updated Nov 13, 2026.
Same NAICS group or Construction & Renovation, nearby first, ranked by score.
Department of Veterans Affairs · Tomah, WI
Why this score
SDVOSB set-aside, 56 days to respond; but small typical award (~$102K).
Department of Veterans Affairs · St. Louis
Why this score
SDVOSB set-aside, new this week; but small typical award (~$102K).
Department of Veterans Affairs · Houston, TX
Why this score
SDVOSB set-aside, 22 days to respond; but small typical award (~$102K).
Department of Veterans Affairs
Why this score
SDVOSB set-aside, 48 days to respond; but small typical award (~$102K).
Federal Prison System / Bureau of Prisons · Allenwood, PA
Why this score
23 days to respond, small-business set-aside; but small typical award (~$111K).
Department of Veterans Affairs · East Orange, NJ
Why this score
SDVOSB set-aside, 40 days to respond; but small typical award (~$102K).
RFP Detector Scores are informational.How we score →
893 open RFPs from this issuer and its offices.
Department of the Army
Why this score
Small-business set-aside, new this week; but only less than a day left.
Department of the Army
Why this score
Small-business set-aside, active buyer ($155M FY24–FY26); but only 1 day left.
Department of the Army
Why this score
New this week; but only 1 day left.
Department of the Army
Why this score
Small-business set-aside, new this week; but only 1 day left.
Department of the Army · Fort Bliss, TX
Why this score
But only 2 days left.
RFP Detector Scores are informational.How we score →
Official federal notice. Updated Nov 24, 2026.
Official solicitation:Sign in free to open the official solicitation
RFP Detector is an independent service and is not affiliated with any government agency. Scores are informational.
RFP Detector is not affiliated with the organization that issued this RFP. Always rely on the official notice and confirm every date and requirement with the issuer.