155mm Modular Artillery for Combat Effectiveness (MACE)
Department of the Army
Why this score
Typical award ~$10.5M, 16 days to respond.
Solicitation # W911S226U4017Updated Aug 10, 2026
This RFP closed on Aug 18, 2026.
Aug 18, 2026
Responses were due Aug 18, 2026, 9:00 AM CDT
Same NAICS group or Supplies, Equipment & Furniture, nearby first, ranked by score.
Department of the Army
Why this score
Typical award ~$10.5M, 16 days to respond.
Why this score
Typical award ~$10.5M, 34 days to respond.
Department of the Army · Picatinny Arsenal, NJ
Why this score
Typical award ~$10.5M, 32 days to respond; but updated 43 days ago.
Defense Logistics Agency
Why this score
SDVOSB set-aside, new this week; but small typical award (~$56K).
Why this score
HUBZone set-aside, new this week; but small typical award (~$56K).
Why this score
WOSB set-aside, new this week; but small typical award (~$56K).
RFP Detector Scores are informational.How we score →
Summary by RFP Detector
Department of the Army (W6QM MICC-FT DRUM), part of the Department of Defense, posted a combined synopsis/solicitation titled “Safety Shower” under solicitation number W911S226U4017. It was posted on Aug 10, 2026. The response deadline was Aug 18, 2026, 9:00 AM CDT. It is classified under NAICS 332913 (Plumbing Fixture Fitting and Trim Manufacturing) and product/service code 4240. The set-aside is listed as Small Business Set Aside - Total. The listed point of contact is David Fortune.
Score at publication
Every RFP starts at 50. Each factor adds or subtracts points compared with a typical RFP; unknown data counts as neutral.
Frozen at publication: closed RFPs are not re-scored.
Starts at 50
No value published, and there isn't enough award history to estimate one. Scored as neutral.
Total small-business set-aside.
2,008 other RFPs from Department of the Army on RFP Detector in the past 12 months; no award history found.
Solicitation, bids due: 8 days to respond (due Aug 18, 2026, 9:00 AM CDT).
Documents not listed, named contact with email and phone, 438-word description.
Posted today.
50 + contributions = 68 (B, Strong)
Informational, not advice to bid or not bid. Score version 1.0.0, evaluated Aug 10, 2026.
Eligibility · Small Business Set Aside - Total
Small-business set-asides reserve a contract, or part of it, for businesses that meet the size standard for the NAICS code on the notice. "Total" set-asides restrict the whole requirement; "partial" set-asides restrict part of it.
Not stated in a form we could extract. See the official solicitation for requirements, evaluation criteria and submission steps.
From the official notice
ATS EcoTower C1D2/26 ? Pneumatic, Skid-Mounted Safety Shower and Eyewash Station (or Equal) Primary Purpose: To provide rapid, compliant, and self-contained emergency decontamination (shower and eye/face wash) in remote locations or harsh environments lacking a potable water source, specifically within hazardous areas. ________________________________________ ???? Core System and Compliance Standards ? Safety Compliance: Must be fully compliant with ANSI/ISEAZ358.1 (2014) standards for emergency eyewash and shower equipment, ensuring continuous flow capabilities ? Electrical Hazard Classification: Must be certified for Class I, Division 2 (C1D2) hazardous locations to prevent ignition risks in environments where flammable gases or vapors may be present________________________________________ ? Water Capacity and Thermal Regulation ? Fluid Capacity: Must include an integrated, heavy-duty insulated water storage tank with a minimum capacity of 325 gallons to guarantee a minimum of 15minutes of continuous tepid water flow. ? Tepid Water Delivery: Must feature an integrated, electrical immersion heating system (minimum 1,200 Watts) to actively maintain stored water temperatures above the ANSI-mandated minimum of 60?F (15.6?C) in freezing or cold-weather conditions ? Freeze Protection: Must utilize a self-regulating heat trace system to protect plumbing and supply lines from freezing down to an ambient operating temperature threshold of 0?F (-17.8?C) ________________________________________???? Pneumatic Operation and Mechanical Specifications ? Pumping System: Must utilize a pneumatically driven transfer pump (rather than electric) to deliver pressurized water to the showerhead and eyewash . This ensures complete spark-free operation in C1D2 zones and allows the unit to safely function during electrical outages via pneumatic backup ?Pneumatic Air Source Input: Must support a shop air compressor supply or specialized nitrogen tank supply with an operational pressure range of 60 to 120 PSI (recommended regulator set to 80 PSI) ? Flow Rates: ? Shower: Must deliver a regulated flow rate of at least 20 GPM (76 LPM) ? Eyewash: Must deliver a regulated flow rate of at least 0.4 GPM(1.5 LPM) with an integrated protective dust/debris cover________________________________________ ???? Structural and Mounting Specifications ? Skid-Mount Design: Must be built on a heavy-duty, corrosion-resistant, powder-coated steel skid frame designed for rapid deployment, positioning by forklift/crane, and high-wind structural stability. ? Footprint and Portability: Must maintain a compact, space-saving footprint suitable for deployment in tight industrial spaces, remote airfields, or forward operating environments ? Material Durability: All critical external piping and the showerhead assembly must be constructed from durable stainless steel or equivalent corrosion-resistant materials. ? Controls and Activation: Must feature a highly visible, easy-to-reach mechanical pull-handle mechanism for instant, hands-free activation of the shower ________________________________________ ? Power Requirements ?Electrical Input: Must operate on standard, readily available utility or generator power:120V, single-phase, 60Hz, 20-Amp draw (typically utilizing a NEMA 5-20 plug configuration)
No documents are listed for this notice.
David Fortune
PrimaryPoints of contact as published on the notice.
Combined Synopsis/Solicitation posted
Responses were due
881 open RFPs from this issuer and its offices.
Department of the Army
Why this score
Small-business set-aside, active buyer ($155M FY24–FY26); but only less than a day left.
Department of the Army · Honolulu, HI
Why this score
Clear, complete notice; but only less than a day left.
Department of the Army · Camp Murray, WA
Why this score
Not openly competed. Notice signals a sole-source or brand-name intent. The largest recipient took 6% of these dollars in FY24–FY26, and spending is spread across many vendors.
Department of the Army · West Point, NY
Why this score
Not openly competed. Notice signals a sole-source or brand-name intent. The largest recipient took 33% of these dollars in FY24–FY26.
Department of the Army · California
Why this score
Small-business set-aside, active buyer ($24.3B FY24–FY26); but only 1 day left.
Department of the Army · Wisconsin Dells, WI
Why this score
Recently updated, clear, complete notice; but only 1 day left.
RFP Detector Scores are informational.How we score →
Official federal notice. Updated Aug 10, 2026.
Official solicitation:Sign in free to open the official solicitation
RFP Detector is an independent service and is not affiliated with any government agency. Scores are informational.
RFP Detector is not affiliated with the organization that issued this RFP. Always rely on the official notice and confirm every date and requirement with the issuer.