Skip to content
FederalSources soughtOpen Federal notice

Sources Sought - Equipment Testing and Program Monitoring Services of Radiology and Quality Programs - VA Black Hills Health Care System

Department of Veterans Affairs› NETWORK CONTRACT OFFICE 23 (36C263) Fort Meade

Solicitation # 36C26327Q0137Updated Nov 25, 2026Scored Nov 26, 2026

Responses due

Dec 3

Dec 3, 2026, 12:00 PM CST

Posted Nov 25Due Dec 3

Summary by RFP Detector

What this RFP is about

Department of Veterans Affairs (NETWORK CONTRACT OFFICE 23 (36C263)) posted a sources sought notice titled “Sources Sought - Equipment Testing and Program Monitoring Services of Radiology and Quality Programs - VA Black Hills Health Care System” under solicitation number 36C26327Q0137. It was posted on Nov 25, 2026. Responses are due Dec 3, 2026, 12:00 PM CST. It is classified under NAICS 811210 (Electronic and Precision Equipment Repair and Maintenance) and product/service code H266. No set-aside is listed. The listed point of contact is ALISHA MILANDER, CONTRACTING OFFICER.

Key facts

Sector
Federal
Notice type
Sources sought
As posted: Sources Sought
PSC
H266
Place of performance
Fort Meade
ZIP 57741
Value
Not statedTypical award in this market ≈ $74.8K
Solicitation #
36C26327Q0137
Listing
Official federal notice

RFP Detector Score

Score breakdown

Every RFP starts at 50. Each factor adds or subtracts points compared with a typical RFP; unknown data counts as neutral.

Starts at 50

  • Value−9.1estimated

    No value published. Typical award is about $75K: the median of 2,935 VA contracts over $25K awarded in NAICS 811210, FY24–FY26.

  • Competition & access+4.5measured

    Full and open competition. The largest recipient took 11% of these dollars in FY24–FY26, and spending is spread across many vendors.

  • Issuer & market+8.1measured

    VA obligated $634M on NAICS 811210 across 4,431 contracts in FY24–FY26. 106 other notices from this office in the past 12 months.

  • Time & stage+1.7measured

    Sources sought (market research, not a bid): 7 days to respond (due Dec 3, 2026, 12:00 PM CST).

  • Clarity & completeness+5.0estimated

    Documents not listed, named contact with email and phone, 2,253-word description.

  • Freshness+9.0measured

    Posted today.

50 + contributions = 69 (B, Strong)

Informational, not advice to bid or not bid. Score version 1.0.0, evaluated Nov 26, 2026.

Requirements & submission

Eligibility · Full and open competition

Full and open competition means the notice states no set-aside: any responsible business can respond, subject to the requirements in the notice.

Not stated in a form we could extract. See the official solicitation for requirements, evaluation criteria and submission steps.

From the official notice

Description

2,253 words

Page 1 of 38 Page 14 of 39 Page 1 of 38 The VA Black Hills Health Care System Fort Meade VA Medical Center, Rapid City CBOC, and Hot Springs VA Medical Center locations is conducting market research in accordance with RFO 17.204-1 Exercise of Options for Equipment Testing and Program Monitoring Services of the Radiology and Quality Programs as described in the Preliminary Statement of Work below. This is a SOURCES SOUGHT NOTICE only looking for businesses to provide the services listed in the Preliminary Statement of Work below for market research purposes. No proposals are being requested or accepted with this notice. THIS IS NOT A SOLICITATION FOR PROPOSALS OR FINAL PRICING AND NO CONTRACT SHALL BE AWARDED FROM THIS NOTICE. This notice shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs. Responses to this notice will be treated only as information for the Government to consider as part of their market research efforts. The information provided will be used by the Government in developing its acquisition strategy regarding possible set aside for Service-Disabled Veteran-Owned, Veteran-Owned, and other socio-economic categories of small business. Interested parties are responsible for adequately marking proprietary, restricted or competition sensitive information contained in their response. The Government does not intend to pay for the information submitted in response to this notice and parties responding will not be entitled to payment for direct or indirect costs incurred in responding to this notice. The North American Industry Classification System (NAICS) code for this requirement is 811210, Electronic and Precision Equipment Repair and Maintenance, with an SBA Small Business Size Standard of $34.0 Million. If you are a vendor capable of providing the requested information and required services described below with competitive pricing, send your information with a description of proof of capability and answers to all questions to: Alisha.Milander@va.gov on or before Thursday, December 3, 2026 at 12:00 PM Central Time. Please provide answers as appropriate to the following questions in the table below with your response to this Sources Sought. Failure to respond accurately to the following questions may affect the acquisition strategy. Failure to respond to the questions at all, or not respond to select individual questions, will result in your response being determined as non-responsive. 1. Please provide all socio-economic categories of your firm (e.g., SDVOSB, VOSB, WOSB, Large Business, 8a, etc.) as well as your firm s SAM Unique Entity ID number (replaces DUNS number) and Government Contract POC. 2. State whether the requested services may be ordered against a government contract awarded to your organization (e.g Federal Supply Schedule (FSS), General Services Administration (GSA), etc.). 3. State if subcontracting is contemplated for this requirement and what percentage of the work will be subcontracted and for what tasks. 4. Provide estimated lead time to deliver a fully functioning solution as described in the Preliminary Statement of Work below. 5. Complete the ITEM INFORMATION directly below this section for market research pricing for the services described in the Preliminary Statement of Work. ITEM INFORMATION ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0001 1.00 JB $___________ $___________ Perform certification via X-ray equipment testing, dose rate testing, and performance monitoring on radiographic fluoroscopy X-ray equipment for the Black Hills Health Care System during the month of April 2027 in accordance with the Statement of Work. Contract Period: Base POP Begin: 12-15-2026 POP End: 12-14-2027 PRINCIPAL NAICS CODE: 811210 - Electronic and Precision Equipment Repair and Maintenance PRODUCT/SERVICE CODE: H266 - Equipment and Materials Testing - Instruments and Laboratory Equipment 0002 1.00 JB $___________ $___________ Perform leak testing of sealed sources for the Black Hills Health Care System during the month of April 2027 in accordance with the Statement of Work. Contract Period: Base POP Begin: 12-15-2026 POP End: 12-14-2027 PRINCIPAL NAICS CODE: 811210 - Electronic and Precision Equipment Repair and Maintenance PRODUCT/SERVICE CODE: H266 - Equipment and Materials Testing - Instruments and Laboratory Equipment 0003 1.00 JB $___________ $___________ Perform leak testing of sealed sources for the Black Hills Health Care System during the month of October 2027 in accordance with the Statement of Work. Contract Period: Base POP Begin: 12-15-2026 POP End: 12-14-2027 PRINCIPAL NAICS CODE: 811210 - Electronic and Precision Equipment Repair and Maintenance PRODUCT/SERVICE CODE: H266 - Equipment and Materials Testing - Instruments and Laboratory Equipment 0004 5.00 JB $___________ $___________ Perform certification via X-ray equipment testing, dose rate testing, and performance monitoring as requested on all newly acquired radiographic fluoroscopy X-ray equipment for the Black Hills Health Care System throughout the period of performance and also perform follow-up testing on existing equipment on an as-needed basis when repairs are made or equipment is changed out requiring re-testing in accordance with the Statement of Work. Contract Period: Base POP Begin: 12-15-2026 POP End: 12-14-2027 PRINCIPAL NAICS CODE: 811210 - Electronic and Precision Equipment Repair and Maintenance PRODUCT/SERVICE CODE: H266 - Equipment and Materials Testing - Instruments and Laboratory Equipment 0005 7.00 EA $___________ $___________ Travel Expenses to perform services in accordance with the Statement of Work. Not to exceed $2,500 per instance. Contract Period: Base POP Begin: 12-15-2026 POP End: 12-14-2027 PRINCIPAL NAICS CODE: 811210 - Electronic and Precision Equipment Repair and Maintenance PRODUCT/SERVICE CODE: H266 - Equipment and Materials Testing - Instruments and Laboratory Equipment PRELIMINARY STATEMENT OF WORK Introduction The Black Hills Health Care System, Facilities Management Department requires a Board Certified diagnostic radiological physicist to perform equipment testing and program monitoring services of the radiology and quality programs at the Fort Meade VA Medical Center, Rapid City CBOC, and Hot Springs VA Medical Center locations. The Board Certified diagnostic radiological physicist shall have the capability to support and service ALL listed radiographic/fluoroscopic x-ray equipment and also provide certification as requested of all newly acquired radiographic/fluoroscopic x-ray equipment throughout the period of performance of the contract and all exercised option years. Requirements General: The Contractor shall provide a Board Certified diagnostic radiological physicist to perform equipment testing as specified in Paragraph 2.b. for all necessary equipment in April of each year (see Paragraph 2.d. Equipment Listing) and program monitoring services of the radiology and quality programs at the Fort Meade VA Medical Center, Rapid City CBOC, and Hot Springs VA Medical Center locations. Services requested also include leak testing of sealed radiation sources as specified in Paragraph 2.c. in April and October of each year for specified equipment (see Paragraph 2.d. Equipment Listing). Additional services include follow-up testing and certification on existing equipment to be done on an as-needed basis as we make repairs or change out equipment that requires certification prior to use. Radiographic Fluoroscopic X-ray Equipment Testing, Dose Rate Testing and Performance Monitoring (All April frequency cycle items in list below) Testing and monitoring will conform to current VHA National Health Physics Program (NHPP) guidelines as noted in the references below. Testing will include but not be limited to: Measurement of radiation output parameters, including beam filtration Testing of automatic control systems such as automatic exposure controls of radiographic systems and automatic exposure rate controls of fluoroscopy systems Assessment of image quality Measurement of appropriate indices of patient doses or dose rates at clinical technique factors with comparison to national standards Measurement of minimum detectable activity of the Thyroid Uptake unit; Monitoring will include but not be limited to: A review of the quality control monitoring performed by technologists. The design will conform to the ACR Technical Standard for Diagnostic Medical Physics Performance Monitoring of Radiologic and Fluoroscopic Equipment and the ACR Technical Standard for Diagnostic Medical Physics Performance Monitoring of Computed Tomography (CT) Equipment , available from the American College of Radiology. Appropriate indices of doses to patients, as estimated by the diagnostic radiological physicist for the technique factors used at the facility, must be posted at or near the control console for each x-ray imaging device. For radiographic equipment, the entrance skin exposure, air kerma, or dose for a patient of typical size must be posted for common radiographic procedures. For fluoroscopic equipment, the entrance skin exposure rate, air kerma rate, or dose rate must be posted for a typical range of patient sizes for common modes of operation, including various image magnification factors, boost mode, if available, continuous fluoroscopy, and for pulsed fluoroscopy at the available pulse rates. For fluoroscopic equipment, the dose per image for each mode of image recording shall also be posted for a patient of typical thickness. Leak Testing of Sealed Sources (All April/October Frequency Cycle Items in Paragraph 2.d. Equipment Listing): Testing and recordkeeping requirements. Each licensee who uses a sealed source shall have the source tested for leakage periodically. The licensee shall keep a record of leak test results in units of micro curies and retain the record for inspection. Method of testing. The wipe of a sealed source must be performed using a leak test kit. The wipe sample must be taken from the nearest accessible point to the sealed source where contamination might accumulate. The wipe sample must be analyzed for radioactive contamination. Test frequency. (1) Each sealed source (except an energy compensation source (ECS)) must be tested at intervals listed (April/October). The Radiation Physicists will provide the wipe test kits, the analysis and the required report. Equipment Listing: Page 1 of 38 Page 15 of 39 Page 1 of 38 Freq Fac Room # Nomenclature Manufacturer Model Serial Number VA AEMS MERS ID Apr FM 217A-145 RADIOG-FLUORO IMAGING SYST (R/F) GE Healthcare OEC ELITE FBXXTE02427 568 MX3387487 Apr FM CS201I-113 R/F UNITS: MOBILE, OEC ELITE CFD (CART) GE Healthcare OEC ELITE CFD FBXXTE03024 568 MX3580117 Apr FM S222-113 R/F UNITS: MOBILE, OEC ELITE CFD (CART) GE Healthcare OEC ELITE CFD FBXXTE03025 568 MX3580118 Apr FM CS201I-113 R/F UNITS: MOBILE, OEC ELITE CFD (C-ARM) GE Healthcare OEC ELITE CFD X0034828007971 568 MX3580488 Apr FM S222-113 R/F UNITS: MOBILE, OEC ELITE CFD (C-ARM) GE Healthcare OEC ELITE CFD X003482007868 568 MX3580489 Apr FM 104-265 MRI Siemens Magnetom Sola 183215 MX2583351 Apr FM 148-113 CT Siemens Definition AS 96286 MX665120 Apr FM 154-113 Spec-CT GE Healthcare Optima NM/CT640 640Y25559 MX2037514 Apr FM 143-113 Radiographic Systems Samsung Electronics GC85A 52RNM3RM900001J MX2040652 Apr FM 143-113 Radiographic Systems Samsung Electronics GC85A 55EVM3EM7000001W MX2287241 Apr FM 143-113 R/F System Siemens Axiom Luminous agile 61059 EE43067 Apr FM 143-113 x-ray mobile Samsung Electronics GM85 55GFM31M400011K MX1973107 Apr FM 143-113 x-ray mobile Samsung Electronics GM85 55GFM31M400012E MX1973112 Apr FM 313OP2-145 xray Dental Intraoral Sirona Heliodent plus 17647 EE38836 Apr FM 313OP3-145 xray Dental Intraoral Sirona Heliodent plus 31019665 MX663076 Apr FM 317-145 xray handheld intraoral Aseptico Inc Nomad pro 2 1001091 MX1882089 Apr FM 318-145 xray Panolypse Planmeca Promax S3 PAN TPX356791 EE38863 Apr FM 155-113 Dose Calibrator Capintec Instruments CRC-25R 250014 EE28935 Apr FM 156-113 Thyroid Uptake System Biodex Medical Systems HIT-W151 KSA1590781 MX419236 Apr/Oct FM 155-113 Cs137 .0001 curies Capintec Instruments CR-15E S8117001-06 none Apr/Oct FM 155-113 Ba133 .000231 curies Capintec Instruments CR-178E S8107001-04 none Apr/Oct FM 155-113 Co57 .99561 curies RadQual BM06E BM06057E11278103 none Apr FM 127-113 Densitometers: Bone: X-Ray GE Healthcare Lunar IDXA 213130MA MX3495174 Apr RCBOC Mobile Mobile MRI Siemens Magnetom AERA 142349 MX2067566 Apr RCBOC 1910 Radiographic System Digital Phillips Corp Digital Diagnost C90 22860092 MX2991885 Apr HS D020-12 Mobile Scanning Systems: CT Siemens SOMATOM DEFINITION AS 95402 EE43219 Apr HS B006-12 R/F System Siemens Axiom Luminous agile 61237 MX423229 Apr HS B002-12 Radiology System Samsung Electronics GC85A 52RNM3FM500001N MX2047221 Apr HS B002-12 xray portable Samsung Electronics GM85 55GFM31M4000014D MX1980227 Apr HS D112A-12 xray Panolypse Planmeca Promax S3 PAN TPXV3062268 MX1655374 Apr HS D112B-12 xray Dental Intraoral dentsply Sirona Heliodent plus 63217 MX1958839 Apr HS D112C-12 xray Dental Intraoral dentsply Sirona Heliodent plus 63234 MX1958841 Apr HS D112E-12 xray Dental Intraoral dentsply Sirona Heliodent plus 63209 MX1958843 Apr/Oct FM 155--113 CSs137 .000199 Curies New England Nuclear NES 356 3560180A-50 None Apr/Oct FM 155-113 Co60 .00005 curies New England Nuclear NES 354 3540579A-49 none Apr/Oct FM 155-113 Ba133 .00029 curies New England Nuclear NES 358 3580479A-02 None Apr/Oct FM 155-113 Co57 RadQual BM06E-57 BM6057E12083117 None Apr/Oct FM 155-113 Co57 RadQual BM01-10 BM011012088101 None Training Requirements: Appropriate vendor staff (as determined by the VA) performing the duties of the Statement of Work shall complete (print, review, and sign) the attached TMS 20939 No Access document. The Contractor shall send signed TMS 20939 documents to the Contracting Officer s Representative Jonathan Maruszewski at jonathan.maruszewski@va.gov. Security: The Contractor shall adhere to only the following IT security sections contained in the IT Contract Security Clause below (VHA Handbook 6500.6): GENERAL Working Hours: Anticipated hours of work will be Monday through Friday from 7:00 am 4:00 pm. Additional hours must be coordinated through the COR/POC. Work will not be performed on weekends or federal holidays. Observed Federal Holidays: New Year s Day Martin Luther King Birthday Washington s Birthday Memorial Day Juneteenth Independence Day Labor Day Columbus Day Veteran s Day Thanksgiving Day Christmas Day References: NHPP X-ray imaging guidance : http://nhpp.med.va.gov/NHPP_Diagnostic_Radiology_Info.asp ARC Technical Standard for Diagnostic Medical Physics Performance Monitoring of Computed Tomography (CT) Equipment. ARC Technical Standard for Diagnostic Medical Physics Performance Monitoring of Radiological and Fluoroscopic Equipment. NCRP Report #102 Medical X-ray, Electron Beam and Gamma-Ray Protection for Energies up to 50MeV (Equipment Design, Performance and Use) NCRP Report # 147 Structural Shielding Design for Medical X-ray Imaging Facilities NCRP Report # 99 Quality Assurance for Diagnostic Imaging Equipment NRC NUREG 1556, Volume 9 Program-Specific Guidance About Medical Use Licenses. Joint Commission Compliance Checklist: Diagnostic Imaging Standards: EC.02.01.01 - PI.02.01.01

Documents

No documents are listed for this notice.

Contacts

Points of contact as published on the notice.

Timeline & history

  1. Sources Sought posted

  2. Responses dueNext · in 7 days

  3. Archive date on the official notice

Federal award history

Market context

Department of Veterans Affairs · NAICS 811210 · FY24–FY26

Typical award (over $25K)
$74.8K
Contracts awarded
4,431
Total obligated
$633.7M
Award size, Department of Veterans Affairs · NAICS 811210 contracts, FY24–FY26 (log scale)
P25 $18.9KMedian $40.7KP75 $106.9KP90 $290.5K

Largest recipients in this market

  • SONOVA USA INC$67.5M11%
  • VARIAN MEDICAL SYSTEMS, INC$49.9M8%
  • OTICON, INC$24.5M4%

Recipients of past awards in this market, not the incumbent of this RFP.

View as table
Fiscal yearObligated ($)
FY20220
FY202370,593,552.73
FY2024185,739,770.01
FY2025222,984,409.68
FY2026225,009,526.71

Federal contract award records, award types A–D, FY24–FY26. Updated Nov 13, 2026.

Similar open RFPs

Same NAICS group or IT & Software, nearby first, ranked by score.

Strong

FY27 TempTrak Monitoring

Department of Veterans Affairs · Bay Pines, FL

FederalSources soughtSDVOSB set-asideIT & Software+1
Posted Nov 24Due Dec 4, 2026, 2:00 PM EST (in 8 days)Federal notice
Strong

GRECC Preventive Maintenance Contract, Durham VAMC

Department of Veterans Affairs · Durham, NC

FederalSolicitationSmall business set-asideIT & Software+1
Posted Oct 22Due Jan 8, 2027, 10:30 AM EST (in 43 days)Federal notice
Strong

36C25527Q0048 - CT Contrast Injector Maintenance Services

Department of Veterans Affairs · Marion, IL

FederalCombined synopsisSDVOSB set-asideIT & Software+1
Posted Nov 4Due Dec 8, 2026, 11:00 AM CST (in 12 days)Federal notice

RFP Detector Scores are informational.How we score →

More from Department of Veterans Affairs

473 open RFPs from this issuer and its offices.

Limited

Pneumatic Tube System Preventive Maintenance

Department of Veterans Affairs · San Juan, PR

FederalSources soughtConstruction & Renovation
Posted Nov 20Due Nov 26, 2026, 12:00 PM AST (in 4 h)Federal notice
Limited

RFQ | Sbar Approved | Bed Rental WD WD Exempt

Department of Veterans Affairs · Tucson

FederalRFQSDVOSB set-asideSupplies, Equipment & Furniture+1
Posted Oct 30Due Nov 26, 2026, 12:00 PM PST (in 8 h)Federal notice
Fair

FY27 NRM (PROJ 573-24-110) BB - Expand Cardiology Service

Department of Veterans Affairs · Gainesville, FL

FederalSpecial noticeSDVOSB set-asideConstruction & Renovation+1
Posted Nov 10Due Nov 26, 2026, 3:30 PM EST (in 8 h)Federal notice
Not competed

Intent to Sole Source Rauland Nurse Call System Services

Department of Veterans Affairs

FederalSpecial noticeIT & Software
Posted Nov 19Due Nov 26, 2026, 3:00 PM CST (in 9 h)Federal notice

RFP Detector Scores are informational.How we score →

About this notice

Official federal notice. Updated Nov 25, 2026.

Official solicitation:Sign in free to open the official solicitation

RFP Detector is an independent service and is not affiliated with any government agency. Scores are informational.

RFP Detector is not affiliated with the organization that issued this RFP. Always rely on the official notice and confirm every date and requirement with the issuer.