Skip to content
FederalSpecial noticeOpen Federal notice

TECHNOLOGY LICENSING OPPORTUNITY: Multi-Channel Atomic Magnetometer (MCAM)

Department of Energy› Triad - DOE Contractor Los Alamos, NM

Solicitation # S-133667Updated Jul 17, 2026Scored Nov 16, 2026

Responses due

Dec 12

Dec 12, 2026, 5:00 PM MST

Posted Jul 17Due Dec 12

Summary by RFP Detector

What this RFP is about

Department of Energy (Triad - DOE Contractor) posted a special notice titled “TECHNOLOGY LICENSING OPPORTUNITY: Multi-Channel Atomic Magnetometer (MCAM)” under solicitation number S-133667. It was posted on Jul 17, 2026. Responses are due Dec 12, 2026, 5:00 PM MST. It is classified under NAICS 334516 (Analytical Laboratory Instrument Manufacturing) and product/service code 6635. No set-aside is listed. The place of performance is Los Alamos, New Mexico. The listed point of contact is Kathleen McDonald.

Key facts

Sector
Federal
Notice type
Special notice
As posted: Special Notice
PSC
6635
Place of performance
Los Alamos, NM
ZIP 87545
Value
Not statedTypical award in this market ≈ $85.4K
Solicitation #
S-133667
Listing
Official federal notice

RFP Detector Score

Score breakdown

Every RFP starts at 50. Each factor adds or subtracts points compared with a typical RFP; unknown data counts as neutral.

Starts at 50

  • Value−8.5estimated

    No value published. Typical award is about $85K: the median of 80 DOE contracts over $25K awarded in NAICS 334516, FY24–FY26.

  • Competition & access+4.9measured

    Full and open competition. The largest recipient took 8% of these dollars in FY24–FY26, and spending is spread across many vendors.

  • Issuer & market−3.7measured

    DOE obligated $18.9M on NAICS 334516 across 103 contracts in FY24–FY26. 83 other notices from this office in the past 12 months.

  • Time & stage+1.4measured

    Special notice: 27 days to respond (due Dec 12, 2026, 5:00 PM MST).

  • Clarity & completeness+5.0estimated

    Documents not listed, 2 named contacts with email, 1,022-word description.

  • Freshness−8.1measured

    Posted 121 days ago.

50 + contributions = 41 (D, Limited)

Score trend, last 30 daysScore history: 51, 41

Informational, not advice to bid or not bid. Score version 1.0.0, evaluated Nov 16, 2026.

Requirements & submission

Eligibility · Full and open competition

Full and open competition means the notice states no set-aside: any responsible business can respond, subject to the requirements in the notice.

Not stated in a form we could extract. See the official solicitation for requirements, evaluation criteria and submission steps.

From the official notice

Description

1,022 words

Unlike conventional multichannel atomic magnetometers that require one vapor cell and one optical system for each sensing channel, the patented Multi-Channel Atomic Magnetometer (MCAM) architecture from Los Alamos National Laboratory replaces many independent atomic magnetometers with a single shared vapor cell and optical system that simultaneously generates multiple independent sensing channels. MCAM is a non-cryogenic multi-channel optical quantum sensor in a single module that captures ultra-faint biomagnetic signals from the brain, heart and other sources with sensitivity approaching that of the cryogenic SQUID-based systems that have defined the field for decades. MCAM delivers that performance at roughly one-tenth the per-channel cost without a drop of liquid helium. The module pairs one large alkali-metal vapor cell with broad pump and probe laser beams read out by a photodiode array, providing 16 independent sensing channels in a single housing, scaling into helmet-style arrays of hundreds of channels, and flexing around the patient rather than forcing the patient into a fixed cryogenic dewar. Together, these attributes more easily allow for magnetoencephalography, magnetocardiography and magnetic-particle imaging while accelerating overall magnetic imaging workflows. Ongoing development is aimed at extending the sensing architecture from the centimeter scale characterized in the current prototype toward micrometer-scale spatial resolution, opening a path into cellular-scale magnetic imaging that current cryogenic and room-temperature arrays cannot address. How it Works The MCAM module operates on the spin-exchange relaxation-free (SERF) regime, in which atomic spins of alkali-metal atoms inside a large, sealed vapor cell are aligned by a circularly polarized broad pump laser beam through optical pumping and then interrogated by a linearly polarized broad probe beam propagating along a nearly parallel path. An external magnetic field of interest tilts the aligned atomic spins by an angle proportional to the field strength, and that tilt rotates the polarization plane of the probe beam through the Faraday effect; a photodiode array reads the optical rotation simultaneously at multiple points across the cell, with each photodiode pixel reporting on its own localized sensing volume. A buffer gas inside the cell restricts atomic motion so that the small cell volumes behind each pixel behave as independent sensing channels, a rear mirror folds the beams back through the cell to shorten the stand-off distance to the magnetic source, and transparent Pyrex wire heaters hold the cell at the operating temperature needed for SERF operation. Technology Description The patented shared-cell architecture generates multiple independent sensing channels from a single vapor cell, a single pump beam, a single probe beam, and a single detector array. A pair of broad, co-propagating laser beams, one for optical pumping and the other for probing, traverses the shared vapor cell to manipulate the internal atomic spins, converting the local magnetic field distribution into a spatially resolved optical signal that is read out by a multi-pixel photodetector. Because the buffer gas inside the cell restricts atomic diffusion, each pixel of the detector reports on its own small, spatially distinct region of the cell; therefore, the single module yields a two-dimensional map of the local magnetic field rather than a single-point measurement. Operation in the SERF regime, together with an integrated heating and shielding arrangement and a fold-back optical geometry that shortens the distance from the sensing volume to the magnetic source, sets the sensitivity floor in the low tens of femtotesla per root hertz at low frequency. A development path has been identified to reduce the effective sensing-volume scale from the roughly 1 cm per-channel footprint of the current prototype toward the 1 ?m range, which would extend the platform from whole-organ mapping into micro-scale magnetic imaging regimes. Architecturally, the MCAM module is engineered for arrays. Because all channels within a single module share one vapor cell, one laser pair, and one optics assembly, the per-channel parts count and tuning effort drop sharply versus designs that stack many single-channel sensors. Fiber-optic coupling between the laser sources and each sensor head lets modules be repositioned independently, so many modules can be tiled into a conformal helmet or surface array that adapts to head or torso shape and supports configurations that rigid large-cell predecessors cannot accommodate. The design is compatible with several alkali-metal and buffer-gas options and with per-module bias coils that allow each module to be tuned individually inside a larger array. Advantages Development path toward micrometer-scale spatial resolution, a roughly four-order-of-magnitude improvement over the current centimeter-scale prototype and an enabler of cellular-scale magnetic imaging Sensitivity at the low tens of femtotesla per root hertz, comparable to cryogenic SQUID arrays, while using a warm vapor, non-cryogenic architecture Roughly tenfold per-channel cost reduction by sharing one vapor cell, one laser pair and one optics set across 16 channels No liquid cryogens, eliminating recurring cryogen costs and simplifying siting, maintenance and shielding Fiber-coupled, repositionable sensor heads that conform to the patient rather than forcing the patient into a fixed dewar Scalable into helmet-style arrays of hundreds of channels, including a size-adjustable pediatric configuration Shorter sensor-to-source stand-off via rear-mirror beam folding, sharpening spatial resolution of biomagnetic sources Market Applications Medical Diagnostic Imaging (magnetoencephalography systems for epilepsy, stroke and neurodegenerative workups; magnetocardiography for arrhythmia and ischemia screening) Pediatric and Adaptive Neuroimaging (size-adjustable MEG helmets, point-of-care brain monitoring) Micro-scale Biomagnetic Imaging (single-neuron and small-circuit brain activity mapping, high-resolution cardiac tissue mapping) Cancer Diagnostics (magnetic nanoparticle imaging for tumor localization and targeted-therapy tracking) Magnetic Resonance Imaging (low-field/ultra-low field, portable MRI, functional brain imaging) Sensing (low-frequency antennas for underground or undersea links, geomagnetic surveying) Instrumentation (fundamental physics, biomagnetism laboratories, multichannel sensor R&D) Development Status: TRL 4 U.S. Patent No. 11,105,865 LA-UR-26-25904 LANL Tech Partnerships: Unlock the Innovative Potential Los Alamos National Laboratory offers a wide range of cutting-edge technologies and capabilities that may provide your company with a competitive edge in the market and unlock the innovative potential that can enhance, refine, and revolutionize your products. LANL’s licensing program focuses on moving inventions developed by our researchers to commercial innovations. Patented and patent pending inventions and copyrighted software are available to existing and start-up companies through exclusive and non-exclusive licensing agreements. For specific discussions, please contact licensing@lanl.gov. Note: This is not a call for external services for the development of this technology. https://www.lanl.gov/engage/collaboration/feynman-center/partner-with-us/licensing-technology m.lanl.gov/tech-search

Documents

No documents are listed for this notice.

Contacts

2 contacts

Points of contact as published on the notice.

Timeline & history

  1. Special Notice posted

  2. Responses dueNext · in 26 days

  3. Archive date on the official notice

Federal award history

Market context

Department of Energy · NAICS 334516 · FY24–FY26

Typical award (over $25K)
$85.4K
Contracts awarded
103
Total obligated
$18.9M
Award size, Department of Energy · NAICS 334516 contracts, FY24–FY26 (log scale)
P25 $28.4KMedian $60.7KP75 $148.8KP90 $448.6K

Largest recipients in this market

  • MR SOLUTIONS INC$1.5M8%
  • FEI COMPANY$1.3M7%
  • NEW ENGLAND RESEARCH, INC.$1.2M6%

Recipients of past awards in this market, not the incumbent of this RFP.

View as table
Fiscal yearObligated ($)
FY20223,054,672.26
FY20233,237,562.52
FY20245,512,043.38
FY20252,576,090.14
FY202610,861,478.51

Federal contract award records, award types A–D, FY24–FY26. Updated Nov 13, 2026.

Similar open RFPs

Same NAICS group or Supplies, Equipment & Furniture, nearby first, ranked by score.

Fair

PCM330E Encoder Procurement

Department of the Air Force · Kirtland AFB, NM

FederalPresolicitationSupplies, Equipment & Furniture
Posted Nov 4Due Nov 25, 2026, 5:00 PM MST (in 9 days)Federal notice
Limited

Q-TAGG: Quantum Trapped-Atom Gravity Gradiometer

Department of Energy · Los Alamos, NM

FederalSpecial noticeSupplies, Equipment & Furniture
Posted Oct 27Due Nov 17, 2026, 5:00 PM MST (in 15 h)Federal notice
Limited

TECHNOLOGY LICENSING OPPORTUNITY: SonicCoat

Department of Energy · Los Alamos, NM

FederalSpecial noticeSupplies, Equipment & Furniture
Posted Sep 10Due Dec 10, 2026, 5:00 PM MST (in 24 days)Federal notice

RFP Detector Scores are informational.How we score →

More from Department of Energy

122 open RFPs from this issuer and its offices.

Limited

Nanomotion, piezo motors for SNS 50mm Slit

Department of Energy · Oak Ridge, TN

FederalRFQSupplies, Equipment & Furniture
Posted Nov 9Due Nov 17, 2026, 2:00 PM EST (in 10 h)Federal notice
Poor

Invitrogen Countess™ 3 FL Automated Cell Counter

Department of Energy · Oak Ridge, TN

FederalRFQSupplies, Equipment & Furniture
Posted Nov 10Due Nov 17, 2026, 5:00 PM EST (in 13 h)Federal notice
Poor

Radio Detection Kit with Accessories - No Alternatives

Department of Energy · New York

FederalSolicitationSupplies, Equipment & Furniture
Posted Nov 4Due Nov 17, 2026, 5:00 PM EST (in 13 h)Federal notice
Limited

Q-TAGG: Quantum Trapped-Atom Gravity Gradiometer

Department of Energy · Los Alamos, NM

FederalSpecial noticeSupplies, Equipment & Furniture
Posted Oct 27Due Nov 17, 2026, 5:00 PM MST (in 15 h)Federal notice

RFP Detector Scores are informational.How we score →

About this notice

Official federal notice. Updated Jul 17, 2026.

Official solicitation:Sign in free to open the official solicitation

RFP Detector is an independent service and is not affiliated with any government agency. Scores are informational.

RFP Detector is not affiliated with the organization that issued this RFP. Always rely on the official notice and confirm every date and requirement with the issuer.