Mobile (1x) and Spirometry (1x) Labs for the CDC
Federal Acquisition Service · Morgantown, WV
Why this score
26 days to respond, new this week; but thin documentation.
Solicitation # W911S226U3970Updated Aug 7, 2026
This RFP closed on Aug 12, 2026.
Aug 12, 2026
Responses were due Aug 12, 2026, 11:45 AM CDT
Same NAICS group or Supplies, Equipment & Furniture, nearby first, ranked by score.
Federal Acquisition Service · Morgantown, WV
Why this score
26 days to respond, new this week; but thin documentation.
Department of the Army · Pennsylvania
Why this score
New this week, typical award ~$1.1M; but thin documentation.
Forest Service · Salt Lake City, UT
Why this score
Small-business set-aside, new this week; but small typical award (~$50K).
Defense Logistics Agency
Why this score
New this week, active buyer ($217M FY24–FY26); but small typical award (~$54K).
Defense Logistics Agency
Why this score
Posted today, active buyer ($217M FY24–FY26); but small typical award (~$54K).
Defense Logistics Agency
Why this score
Active buyer ($217M FY24–FY26), new this week; but small typical award (~$54K).
RFP Detector Scores are informational.How we score →
Summary by RFP Detector
Department of the Army (W6QM MICC-FT DRUM), part of the Department of Defense, posted a combined synopsis/solicitation titled “Trailer” under solicitation number W911S226U3970. It was first posted on Aug 6, 2026 and has been updated once since. The response deadline was Aug 12, 2026, 11:45 AM CDT. It is classified under NAICS 336212 (Truck Trailer Manufacturing) and product/service code 4210. No set-aside is listed. The listed point of contact is Andre Bishop.
Score at publication
Every RFP starts at 50. Each factor adds or subtracts points compared with a typical RFP; unknown data counts as neutral.
Frozen at publication: closed RFPs are not re-scored.
Starts at 50
No value published, and there isn't enough award history to estimate one. Scored as neutral.
Full and open competition.
2,008 other RFPs from Department of the Army on RFP Detector in the past 12 months; no award history found.
Solicitation, bids due: 6 days to respond (due Aug 12, 2026, 11:45 AM CDT). Tight.
Documents not listed, named contact with email and phone, 809-word description.
Posted today.
50 + contributions = 62 (C, Fair)
Informational, not advice to bid or not bid. Score version 1.0.0, evaluated Aug 6, 2026.
Eligibility · Full and open competition
Full and open competition means the notice states no set-aside: any responsible business can respond, subject to the requirements in the notice.
Not stated in a form we could extract. See the official solicitation for requirements, evaluation criteria and submission steps.
From the official notice
The purpose of this amendment is to attach the graphics requirements and provide additional specifications for the trailer height, UPS system, EIA equipment rack, roof-mounted antennas, and exterior monitor. Procurement: 42 ft. Mobile Command Center (MCC) TrailerSCOPE:The contractor shall design, manufacture, and deliver one (1) custom-built, heavy-duty Mobile Command Center (MCC) trailer. The MCC will serve as a multi-agency incident command post for FES, Police, Guards, and Garrison Command Staff during large-scale emergencies.PLATFORM AND EXTERIOR SPECIFICATIONS:Dimensions: Minimum 42 ft. Length x 8 ft. Width (nominal).Hitch Type: Heavy-duty 5th-Wheel Kingpin (or Gooseneck) configuration, matched to a GVWR appropriate for the fully loaded trailer.Slide-Outs: Minimum of two (2) flat-floor slide-outs to maximize interior operational space.Leveling System: Heavy-duty automatic hydraulic leveling system (minimum 4-point).Awning: One (1) heavy-duty motorized awning on the curbside, positioned to cover the exterior monitor, with an automatic wind-retraction sensor.Graphics: Full custom exterior vinyl wrap with Department of War / Garrison FES branding and reflective striping (graphics package to be approved by the Government post-award).Lighting:Minimum of two (2) high-lumen LED scene lights per side (8 total).Full emergency warning light package (Red/Blue LEDs) conforming to emergency vehicle standards.POWER AND CLIMATE CONTROL:Generator: Minimum 20kW Onan (or equivalent) commercial-grade diesel generator with remote interior start and custom fabricated fuel cell.Climate Control: Three (3) 15,000 BTU roof-mounted HVAC units with heat pumps/strips, ducted for even air distribution, capable of maintaining 70?F interior temperature in extreme high-heat environments (110?F+ ambient).Shore Power: Heavy-duty shore power connection (e.g., 50A or 100A as appropriate for load) with a minimum 50-foot heavy-duty male-end umbilical cord.Power Protection: Rack-mounted Uninterruptible Power Supply (UPS) sized to support the communications and server rack to prevent drop-outs during power transition.INTERIOR LAYOUT AND FINISHES:Zones: Trailer must be divided into a Main Operations Area and a secure Conference Area, separated by a sound-deadening door. No lavatory or kitchenette to be included.Workstations: Six (6) total dedicated workstations. One (1) workstation must be customized specifically for a Dispatch Console.Desks/Cabinetry: Heavy-duty, commercial-grade desks and overhead/under-desk aluminum or high-pressure laminate storage cabinetry for each workstation.Whiteboards: Two (2) large magnetic dry-erase whiteboards (one in the main area, one in the conference area).COMMUNICATIONS AND TECHNOLOGY:Server Rack: Minimum one (1) full-height or half-height 19 inch EIA equipment rack structurally mounted and cooled.Radio Prep: Pre-wired for Government Furnished Equipment (GFE) Motorola and Harris radios. Must include roof-mounted antenna bases and coaxial cable runs to all six (6) workstations.Network/Data: Trailer must be pre-wired with CAT6 ethernet drops at all workstations, routed back to the server rack, ready for Government-installed FirstNet routing equipment.Monitors:One (1) large touchscreen interactive monitor mounted in the Conference Area. Interior Height: Thetrailer must have a minimum interior height of 80 inches (6 ft. 8 inches). This ensuresadequate head clearance for personnel and allows for the installation of overhead LEDlighting, wire runways, and ducted HVAC systems without restricting movement. ExteriorHeight: The overall exterior height of the trailer must not exceed 12 feet 6 inches (150inches) in its stowed/transport configuration. This measurement must include all roofmountedequipment, such as low-profile HVAC units, stowed light towers, and antennas, toguarantee clearance under standard highway bridges and overpasses. Runtime: The UPSsystem must be capable of powering all critical communication and network routingequipment for a minimum of 30 minutes under a full operational load. This runtime isintended to act as a power bridge, allowing safe power transition between Shore Power andthe onboard generator, or enabling a graceful shutdown of critical systems during a powerfailure. Wattage/Capacity: The syFor tstem must support a minimum continuous load of3,000VA / 2,700 Watts. The vendor must supply a double-conversion online UPS to ensuresensitive radio and IT equipment receive clean, regulated power, isolated from voltagespikes or generator sags. Rack Units (RU): The equipment rack must provide a minimumof 16U of usable rack space to accommodate patch panels, network switches, routers, theUPS, and radio chassis, while leaving room for future expansion. Rack Depth: The rackmust have a minimum usable depth of 25 inches (front-to-back rail depth) to safely housedeeper server-style equipment and the UPS chassis. The rack must also feature front andrear adjustable mounting rails and robust rear cable-management brackets designed towithstand transit vibration. Antenna Bases: The trailer must be equipped with a minimumof 6 roof-mounted antenna bases (standard threaded NMO mounts). Installation Detail: Thebases must be spaced at least 3 feet apart to prevent RF interference. They must be prewiredto the internal EIA equipment rack using low-loss coaxial cable (such as LMR-400or equivalent) and must include solid copper grounding planes integrated into the roofstructure. Monitor Size: The exterior display must be a 49-inch to 55-inch high-brightness,daylight-readable (minimum 1000 nits), commercial-grade outdoor monitor. Mounting andHousing: The monitor must be permanently housed in a recessed, weatherproof, andlockable exterior compartment rather than a removable mount. The compartment mustfeature gas-shock-assisted doors, integrated LED compartment lighting, and a heavy-dutyarticulating pull-out mount that allows the monitor to be angled for group briefings. Allexterior graphics require Government approval prior to application.
No documents are listed for this notice.
Andre Bishop
PrimaryPoints of contact as published on the notice.
Combined Synopsis/Solicitation posted
Combined Synopsis/Solicitation posted
Responses were due
917 open RFPs from this issuer and its offices.
Department of the Army
Why this score
New this week, 8(a) set-aside; but only 1 day left.
Department of the Army
Why this score
Small-business set-aside, recently updated; but only 1 day left.
Department of the Army · Orlando, FL
Why this score
Active buyer ($6.5B FY24–FY26), typical award ~$1.5M; but only 2 days left.
Department of the Army · Fort Irwin, CA
Why this score
Clear, complete notice; but only 2 days left.
Why this score
Active buyer ($24.3B FY24–FY26), full and open; but only 2 days left.
Department of the Army · JBSA Ft Sam Houston, TX
Why this score
Small-business set-aside, active buyer ($1.3B FY24–FY26); but only 2 days left.
RFP Detector Scores are informational.How we score →
Official federal notice. Updated Aug 7, 2026.
Official solicitation:Sign in free to open the official solicitation
RFP Detector is an independent service and is not affiliated with any government agency. Scores are informational.
RFP Detector is not affiliated with the organization that issued this RFP. Always rely on the official notice and confirm every date and requirement with the issuer.